Operator Status

The operator status screen shows the current status of the operators working on the Eton line. See Work Modes for working time reference.

There are two tabs: Production and Work time.

Functionality

  • The view can be filtered by the operators login state.
  • The view can be filtered by station groups.

Production - Operator level grid

Contents

  • The employee number
  • The employee name
  • The current workstation number
  • The number of produced units
  • The number of faults
  • The SMV
  • The Piece rate value
  • The on standard time
  • The off standard time
  • The operator performance

The operator performance is calculated by following formula:

Operator performance = [The SMV] / [The on standard time]

  • The operator efficiency

The operator efficiency is calculated by following formula:

Operator efficiency = [The SMV] / [The total time]

Functionality

  • By clicking on the arrow in the leftmost column you can show the operator production stats on an operation level.
  • By right clicking you can access the Station Config, given that the row´s operator is logged in at a station.

Production - Operation level grid

Contents

  • The operation id
  • The operation name
  • The number of produced units
  • The number of faults
  • The SMV
  • The Piece rate value
  • The on standard time
  • The off standard time
  • The operator performance

The operator operation performance:

Operator operation performance = [The SMV] / [The on standard time]

Functionality

Work time grid

Contents

  • The employee number
  • The employee name
  • The current workstation number
  • The log in time
  • The on standard time (the time an operator is working against an SMV)
  • The off standard time (the time an operator is working in an off std category)
  • The paused time
  • The total work time